Owens Corning metal building Insulation will help you meet the tough industry standards. Includes Elaminator Insulation and OptiLiner banded liner system. Get the most out of your insulation materials with Owens Corning. Other Products We offer an entire line of accessory products for your metal building insulation needs. Accessories We offer a variety of accessories, including patch tape and column and wrack protection devices, to suit all of your building needs. MORE>> Reflect. Metal Building Insulation Our insulation is formaldehyde free, making it very user friendly. It is itch, odor, and dust-free as well. Venture tape for fiberglass duct boards, patch tape for systems such as the Skyrider, white banding for High R value systems and. We are specialists in Metal Building Insulation with a strong focus on both Commercial and Agricultural products. Woven Repair Tape Patch tape for bi-directional woven fabrics. This would be the repair tape for the Mai Weave Tuff Face product we offer. Metal Building Insulation Metal Roof Insulation SCIF Ultra NT Duct Insulation Agricultural Under Concrete Slab Insulation Wall Insulation Roof Insulation. Insulation Metal Building Insulation (MBI) Canam Steel Building Corporation offers a complete line of metal building insulation products. From single layer to high R-value systems, all fiberglass is NAIMA 202-96 Insulation Tape, Patch Tape, Steel Banding, Stick Pins and Washers. Insulation Products for Attaching, Hanging and Installing Metal Building Insulation Rolls. Bar Joist Support Clips 'L' shaped bar joist support clips are placed through the center or on the. The pros at Eagle National Steel can help you pick from our selection of insulation, double-sided insulation tape, insulation patch tape. We look forward to assisting you with your steel building insulation needs at Eagle National Steel serving the DFW Reviews. These metal building insulations are certified by NAHB for flexible fiberglass used in metal buildings that occur during installation. Steel Building Accessories - Metal Building Insulation Canam Steel Building Corporation offers a complete line of metal building. Therm-All's resident code expert and District Manager Bill Beals provides tips for better understanding commercial energy codes. Read More >> NOT ALL INSULATION IS CREATED EQUAL Find out why you should buy metal building insulation from us. SECTION 0. 72. 10 THERMAL INSULATIONSECTION 0. THERMAL INSULATION Copyright 2. ARCAT, Inc. We offer several high R value system options including our Energy Saver FP and Purlin Glide FP, which provide OSHA compliant leading edge fall protection when installed according to our instructions and by a Silvercote Lamination LLC certified installing contractor. We are proud to present this site, featuring IQWeb, which gives building professionals the ability to get precise, guaranteed insulation quotes and buy quality insulation materials via the internet. The following is one example of how a mock- up on a large project might be specified. When deciding on the extent of the mock- up, consider all the major different types of work on the project. C. Mock- Up: Provide a mock- up for evaluation of surface preparation techniques and application workmanship. Finish areas designated by Architect. Do not proceed with remaining work until workmanship, color, and sheen are approved by Architect. Refinish mock- up area as required to produce acceptable work. DELIVERY, STORAGE, AND HANDLINGA. Store products in manufacturer's unopened packaging elevated above ground or slab, preferably on a flat surface, to prevent contact with surface water until ready for installation. B. Store products with labeling intact including material name, production date and product code, until ready for installation. A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's recommended limits.** NOTE TO SPECIFIER ** Delete if not required. A. Fiberglass Insulation Warranty: 1. Silvercote Lamination LLC (. Liability under this warranty is limited, at Silvercote's exclusive option, to Silvercote in replacing defective Insulation without charge at the place of Silvercote's original delivery or, in the alternative, a refund of 1. Silvercote's original selling price for such defective Insulation. Labor charges or other costs incurred with removal or installation of either the original or replacement Insulation are not covered by this warranty. Liability under this warranty is limited, at Silvercote's exclusive option, to Silvercote replacing defective Product without charge at the place of Silvercote's original delivery or, in the alternative, a refund of the original purchase price for such defective Product. In those instances in which Silvercote determines that only a portion of the Product manifests a defect, Silvercote reserves the right to limit any replacement or refund to the portion of the Product that manifests the defect. For purposes of this limited warranty, the term . Only pre- installation R- value is covered by this warranty. The period of this warranty shall be ninety days from the date of purchase by the original purchaser or until the first installation of the Product or any part thereof, whichever occurs sooner. A. Acceptable Manufacturer: Silvercote, LLC, which is located at: 2. Logue Ct.; Greenville, SC 2. Toll Free Tel: 8. Email: request info (support@silvercote. Web: www. silvercote. NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions. B. Substitutions: Not permitted. C. Requests for substitutions will be considered in accordance with provisions of Section 0. NOTE TO SPECIFIER ** Delete if not required. ROOF AND WALL UN- FACED INSULATION SYSTEM** NOTE TO SPECIFIER ** Varying degrees of R value can be obtained depending on the physical space available. Common sizes are below. A. Typical Energy Saver FP R- values: 1. Retrofit Roof system R- values (pre- installed). R- 1. 9: 6 inches (1. R- 2. 5: 8 inches (2. R- 3. 0: 9- 1/2 inches (2. R- 3. 0: 9- 1/2 inches (2. R- 1. 9 + R- 1. 1). R- 3. 2: 1. 0 inches (2. R- 1. 9 + R- 1. 3). R- 3. 3: 1. 0- 3/4 inches (2. R- 2. 5 + R- 8). 4)R- 3. R- 2. 5 + R1. 0). R- 3. 8: 1. 1 inches (2. R- 2. 8 + R- 1. 0). R- 4. 0: 1. 2 inches (3. R- 3. 0 + R- 1. 0). R- 4. 3: 1. 3 inches (3. R- 3. 0 + R1. 3). R- 4. 9: 1. 5- 1/2 inches (3. R- 3. 0 + R- 1. 9). Triple Layer Systems (typically used in 1. The labeled R value on the label shall be the sum of the R values equal to an R value of . The fabric shall be fastened to the inside of the purlins and girts in a metal building and is supported by the banding. The insulation is positioned between the fabric and the roof or wall panels. This is a free certification program which can be performed online. If the installing contractor is not certified, the Energy Saver is still a fabric liner system and will provide the same thermal performance, but is not an OSHA compliant fall protection system. Energy Saver FP is fall protection at the leading edge only and is only one component of a total fall protection plan for the job. Perimeter fall protection is still required. Energy Saver FP should not be relied upon for fall protection within 6 feet (1. Other means of fall protection must always be used in those areas. Delete if not required. The system shall provide OSHA- compliant leading edge fall protection. The combination of the banding, fabric, screws, and banding clips shall contribute the designed strength characteristics necessary to pass the OSHA requirements for leading edge fall prevention (2. CFR 1. 92. 6. 7. 54 (e)(3)(i)). Energy Saver FP is fall protection at the leading edge only and is only one component of a total fall protection plan for the job. Perimeter fall protection is still required. Energy Saver FP should not be relied upon for fall protection within 6 feet (1. Other means of fall protection must be used in those areas. To meet OSHA guidelines an insulation support and fall prevention system shall restrain and support 4. If a third layer is required based on the total system thickness, it shall also be installed parallel to the purlins. Any layers running parallel to the purlins are to be fabricated at a width that will fill each purlin space. Product: Fiberglass blanket insulation as manufactured by Silvercote Lamination LLC. Fabric: The fabric shall be woven reinforced high- density polyethylene yarns coated on both sides with a continuous white or colored polyethylene film. The fabric is folded or rolled (based on erector preference) to allow for rapid pullout on the strap support system and is 2. FHC rated per ASTM E- 8. The fabric shall be provided in large custom fit pieces by hot air welding to fit the bay size. Product: Energy Saver FP Fabric as manufactured by Silvercote Lamination LLC. Banding: 1 inch (2. ASTM A6. 53- 0. 5A) zinc coated, primed, and painted white for corrosion resistance. Minimum thickness of . Banding Clips: Banding clips shall be installed around the perimeter of the system in locations required by manufacturer's design. The clips shall be fastened with a single 1- 1/4 inches (3. TEK5 self- drilling screw into the end wall rafters and a single 3/4 inch (1. TEK3 self- drilling screw into the eave struts. Product: Patented Energy Saver FP Banding Clips as manufactured by Silvercote Lamination LLC.** NOTE TO SPECIFIER ** Perfect ' R' was designed to improve on an insulating concept which involves the application of a vapor retarder (facing) and unfaced fiberglass by means of dispensing machines. This method improves interior appearance dramatically because all facing seams are made on top of the purlins leaving a smooth finish on the building interior. Additionally, the roof system can be installed faster than when using faced metal building insulation with stapling tabs. Delete if not required. C. Acceptable roof insulation system shall be the Perfect R System as manufactured by Silvercote Lamination LLC with an R value of . The labeled R value on the label shall be the sum of the R values equal to an R value of . System shall provide a continuous vapor retarder to reduce interior condensation. Tab stapling as part of the vapor retarder is not acceptable. System shall provide a smooth seamless appearance: 5. System shall position and apply the facing to a preset droop depth to allow the insulation to expand fully to achieve maximum thermal performance.** NOTE TO SPECIFIER ** Delete if not required. System machines shall be optimized for use over Sky Web II Fall Protection Safety Netting. Maximum roof pitch 4: 1. Delete if not required. D. Acceptable roof system shall be the Purlin Glide FP system as manufactured by Silvercote Lamination LLC, Greer, South Carolina, with a pre- installed R- value of . Delete if not required. Roof system shall be a double layer system. System shall consist of an efficient method of applying metal building insulation to pre- engineered buildings using wide rolls of cross- woven polyethylene fabric draped over the top of the roof purlins or bar joists. Purlin Glide FP Insulation System is a patented system.** NOTE TO SPECIFIER ** The Purlin Glide FP(TM) Insulation System must be installed by a GLBPI certified installing contractor in order to provide leading- edge fall protection. This is a free certification program which can be performed online. If the installing contractor is not certified, the system is still a fabric liner system and will provide the same thermal performance, but is not an OSHA compliant fall protection system. The Purlin Glide FP(TM) Insulation System is fall protection at the leading edge only and is only one component of a total fall protection plan for the job. Perimeter fall protection is still required. The Purlin Glide FP(TM) Insulation System should not be relied upon for fall protection within 6 feet (1. Other means of fall protection must always be used in those areas. Delete if not required. The system shall provide OSHA- compliant leading edge fall protection. The system shall provide the designed strength characteristics necessary to pass the OSHA requirements for leading edge fall prevention (2. CFR 1. 92. 6. 7. 54 (e)(3)(i)).
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
December 2016
Categories |